Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
NMR Biomed ; 36(8): e4923, 2023 08.
Artículo en Inglés | MEDLINE | ID: covidwho-2274196

RESUMEN

Hyperpolarized 129 Xe MRI (Xe-MRI) is increasingly used to image the structure and function of the lungs. Because 129 Xe imaging can provide multiple contrasts (ventilation, alveolar airspace size, and gas exchange), imaging often occurs over several breath-holds, which increases the time, expense, and patient burden of scans. We propose an imaging sequence that can be used to acquire Xe-MRI gas exchange and high-quality ventilation images within a single, approximately 10 s, breath-hold. This method uses a radial one-point Dixon approach to sample dissolved 129 Xe signal, which is interleaved with a 3D spiral ("FLORET") encoding pattern for gaseous 129 Xe. Thus, ventilation images are obtained at higher nominal spatial resolution (4.2 × 4.2 × 4.2 mm3 ) compared with gas-exchange images (6.25 × 6.25 × 6.25 mm3 ), both competitive with current standards within the Xe-MRI field. Moreover, the short 10 s Xe-MRI acquisition time allows for 1 H "anatomic" images used for thoracic cavity masking to be acquired within the same breath-hold for a total scan time of about 14 s. Images were acquired using this single-breath method in 11 volunteers (N = 4 healthy, N = 7 post-acute COVID). For 11 of these participants, a separate breath-hold was used to acquire a "dedicated" ventilation scan and five had an additional "dedicated" gas exchange scan. The images acquired using the single-breath protocol were compared with those from dedicated scans using Bland-Altman analysis, intraclass correlation (ICC), structural similarity, peak signal-to-noise ratio, Dice coefficients, and average distance. Imaging markers from the single-breath protocol showed high correlation with dedicated scans (ventilation defect percent, ICC = 0.77, p = 0.01; membrane/gas, ICC = 0.97, p = 0.001; red blood cell/gas, ICC = 0.99, p < 0.001). Images showed good qualitative and quantitative regional agreement. This single-breath protocol enables the collection of essential Xe-MRI information within one breath-hold, simplifying scanning sessions and reducing costs associated with Xe-MRI.


Asunto(s)
COVID-19 , Isótopos de Xenón , Humanos , Pulmón/diagnóstico por imagen , Respiración , Contencion de la Respiración , Imagen por Resonancia Magnética/métodos , Gases
2.
Magn Reson Imaging ; 96: 135-143, 2023 02.
Artículo en Inglés | MEDLINE | ID: covidwho-2229908

RESUMEN

Patients recovered from COVID-19 may develop long-COVID symptoms in the lung. For this patient population (post-COVID patients), they may benefit from longitudinal, radiation-free lung MRI exams for monitoring lung lesion development and progression. The purpose of this study was to investigate the performance of a spiral ultrashort echo time MRI sequence (Spiral-VIBE-UTE) in a cohort of post-COVID patients in comparison with CT and to compare image quality obtained using different spiral MRI acquisition protocols. Lung MRI was performed in 36 post-COVID patients with different acquisition protocols, including different spiral sampling reordering schemes (line in partition or partition in line) and different breath-hold positions (inspiration or expiration). Three experienced chest radiologists independently scored all the MR images for different pulmonary structures. Lung MR images from spiral acquisition protocol that received the highest image quality scores were also compared against corresponding CT images in 27 patients for evaluating diagnostic image quality and lesion identification. Spiral-VIBE-UTE MRI acquired with the line in partition reordering scheme in an inspiratory breath-holding position achieved the highest image quality scores (score range = 2.17-3.69) compared to others (score range = 1.7-3.29). Compared to corresponding chest CT images, three readers found that 81.5% (22 out of 27), 81.5% (22 out of 27) and 37% (10 out of 27) of the MR images were useful, respectively. Meanwhile, they all agreed that MRI could identify significant lesions in the lungs. The Spiral-VIBE-UTE sequence allows for fast imaging of the lung in a single breath hold. It could be a valuable tool for lung imaging without radiation and could provide great value for managing different lung diseases including assessment of post-COVID lesions.


Asunto(s)
COVID-19 , Síndrome Post Agudo de COVID-19 , Humanos , COVID-19/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Contencion de la Respiración , Imagenología Tridimensional/métodos
3.
Tomography ; 8(2): 999-1004, 2022 04 02.
Artículo en Inglés | MEDLINE | ID: covidwho-1776349

RESUMEN

Thoracic spine CTs are usually performed during free breathing and with a narrow field of view; this common practice systematically excludes the assessment of lungs and other extraspinal structures, even if these have been irradiated during the examination. At our institution we perform thoracic spine CT during breath hold with additional full FOV reconstructions; this allows us to also evaluate lungs and extraspinal pathologies in the same examination with no added costs or further radiation exposure. If this simple and costless technical change is routinely applied to thoracic spine CT many concomitant extraspinal pathologies can be ruled out, from neoplasms to pneumonia; the suggested modification also allows an early diagnosis and avoids recalling and re-irradiating the patient in case these findings are partially included in the study. This practice can be further useful during the current pandemic in order to screen any lung opacities suspicious for COVID-19.


Asunto(s)
COVID-19 , Fracturas de la Columna Vertebral , Contencion de la Respiración , COVID-19/diagnóstico por imagen , Humanos , Pulmón/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tórax , Tomografía Computarizada por Rayos X
4.
Complement Ther Clin Pract ; 41: 101248, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: covidwho-856608

RESUMEN

AIM: to compare anulom vilom pranayama (AVP), kapal bhati pranayama (KBP), diaphragmatic breathing exercises (DBE), and pursed-lip breathing (PLB) for breath holding time (BHT) and rating of perceived exertion (RPE). Methods- Participants were assessed for BHT and RPE, before training on any one intervention using online platforms, for one week during lockdown from COVID-19.15 participants in each group total N = 60 at- (α - 0.05), (1- ß - 0.90) & (effect size - 0.55); were analysed. Results - AVP & DBE decreased RPE (p < 0.000). KBP & PLB did not decrease RPE as compared to AVP & DBE (p. > 0.05). DBE increased BHT more than KBP & PLB interventions (p < 0.05), but not more than AVP (p > 0.05). One-way ANOVA of four interventions revealed significant variation for RPE change (p < 0.05), for AVP. Conclusions - AVP reduces RPE maximally during breath-holding, whereas DPE increases BHT more.


Asunto(s)
Ejercicios Respiratorios , COVID-19 , Intervención basada en la Internet , Interocepción , Esfuerzo Físico/fisiología , Terapia por Relajación , Adulto , Análisis de Varianza , Contencion de la Respiración , Ejercicios Respiratorios/métodos , Ejercicios Respiratorios/psicología , COVID-19/epidemiología , COVID-19/prevención & control , COVID-19/psicología , Femenino , Humanos , Masculino , Medicina Tradicional , Terapia por Relajación/métodos , Terapia por Relajación/psicología , Yoga/psicología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA